Together AI Ships Preemptible GPU Nodes at Half On-Demand Price
Together AI's preemptible GPU nodes cost a flat 50% of on-demand rates with no bidding. The catch: reclamation can kill jobs at any moment, and only checkpointed workloads recover.
By Daniel Okafor
4 min read
What's News
- Preemptible GPU nodes went GA on November 24, 2026, at a flat 50% of on-demand rates across all regions.
- Reclamation allows a drain window of at most five minutes and no minimum node lifetime.
- Usage is metered every one to two minutes and billed sub-hourly.
- Preemptible capacity targets must be set in multiples of eight GPUs.
- Only Slurm jobs submitted with --requeue are resubmitted after a node removal.
Together AI cut GPU cluster prices in half on November 24, 2026, when it made preemptible GPU compute generally available across all regions of Together GPU Clusters. The interruptible nodes run on the same NVIDIA accelerated compute as standard nodes. They cost a flat 50% of the on-demand rate, with no spot market and no bidding.
The fixed discount is the story's core mechanism. Customers pay a predictable rate even though the capacity itself is not guaranteed. Usage is metered every one to two minutes and billed sub-hourly, so customers pay approximately for the minutes a node runs rather than a full hour. A workload that survives interruption gets near-half-price NVIDIA capacity. A workload that does not loses work, money and time.
How does the product actually work?
Preemptible nodes draw from unused supply. When that capacity is needed elsewhere, Together AI reclaims it. Customers can add preemptible capacity when creating a cluster or attach it to a cluster already running.
Standard nodes remain the default. They provision synchronously and are never preempted. Preemptible nodes fill in asynchronously as spare capacity becomes available. Customers cannot convert a node between the two types in place.
The documentation separates two metrics: desired_preemptible_gpus and allocated_preemptible_gpus. That distinction shows customers when live capacity falls short of the target they set. Targets must be set in multiples of eight GPUs.
After a reclamation, the cluster keeps its target and automatically provisions replacement nodes as spare capacity returns. No new capacity request is needed. The refill is automatic.
What happens when a node gets reclaimed?
Reclamation starts with a drain window of at most five minutes. It ends with node removal, finished work or not. There is no minimum node lifetime. A job can lose its worker at any point and must resume when replacement capacity arrives.
That structure puts recovery design at the center of the cost decision. Together AI recommends the capacity only for checkpointed or retryable work: short experiments, configuration sweeps, fine-tuning, evaluations, distillation, batch inference and temporary inference bursts.
The economics work like an insurance policy priced in compute. For a sweep or an internal inference spike, teams can raise the target and lower it later while the cluster keeps running, instead of holding standard capacity sized for peak demand. The company said it already runs preemptible clusters for internal research, development, testing and non-critical production workloads, spreading spare capacity across product teams.
Unsuitable workloads are named plainly: multi-day runs without checkpoints, user-facing serving without fallback, and workloads with strict service-level objectives.
Do Kubernetes and Slurm handle reclamation the same way?
No, and the difference is the sharpest fine print in the launch.
On Kubernetes, reclamation cordons the node, emits a TogetherPreemptionNotified warning and sends pods a SIGTERM shutdown signal. Workloads can set terminationGracePeriodSeconds to use up to the full five-minute drain window for checkpointing and exit. Pods without that setting get the Kubernetes default of 30 seconds. A together.ai/compute-class node label lets teams target interruptible workers to preemptible nodes while coordinators, login pods and user-facing serving replicas stay on standard nodes.
Slurm is blunter. Preemptible and standard nodes share partitions and the same scheduling feature, so the scheduler cannot target preemptible nodes or keep a job off them. Jobs still running when a node is removed are killed. Only jobs submitted with --requeue are resubmitted. A requeued job resumes from its last checkpoint, and any work completed after that checkpoint is lost.
Kubernetes workloads can use the full drain window. Slurm jobs need requeue logic to survive.
What are the limits teams should check first?
A cluster can consist entirely of preemptible nodes. Together can then reclaim all of them. Data on shared volumes persists, but shared volumes and the Slurm control plane remain reachable while no nodes are running only in some regions, and only on a best-effort basis. Teams needing continuously reachable shared storage must keep at least one standard node in the cluster.
The discount only pays off when workloads checkpoint and retry, because reclamation can kill work at any moment. Together AI has effectively turned its spare GPU supply into a fixed-discount product. Whether that price is a bargain or a loss depends on workload design: checkpoints, retry logic and standard-node fallback determine whether reclamation is a recoverable interruption or lost progress and an outage.
Source: unite.ai
More from Daniel Okafor
Show full bio
Correspondent covering money, funding and market shifts around entrepreneurship, startups and venture funding at Business Bearings.